Material Safety Data Sheet

EPO-TOXY™ Epoxy Base


Product Name: EPO-TOXY™ TYPE 1 EPOXY RESINS #957 1
Effective Date: 11/11/85 Date Report Printed: 11/11/85 Product Code 957

INGREDIENTS

Renclion products of epicholorohydrin  76-80%
and bispheon a
AlkyI Glycidyl Ether                   20-24%

Substances listed in the Ingredients Section are those identified as being present at a concentration of 1% greater1 or 0.1% if the substance on the list of potential carcinogens cited on OSHA Hazard Communication Standard. When proprietary ingredient shows, the identity of this substance may be made available as provided in 29 CFR 1910.1200(1).

PHYSICAL DATA

BOILING POINT:  None.
VAP PRESS:      Not applicable.
VAP DENSITY:    Heavier than air.
SQL. IN WATER:  None.
SP. GRAVITY:    1.12-1.14
APPEARANCE:     Straw colored liquid.
ODOR:           Mild aromatic odor.

FIRE AND EXPLOSION HAZARD DATA

FLASH POINT:  245°F
METHOD USED:  PMCC
FLAMMABLE LIMITS
LFL:  Not determined.
UFL:  Not determined.

EXTINGUISHING MEDIA:  Foam, CO2, Dry Chemical
FIRE AND EXPLOSION HAZARDS: None.
FIRE-FIGHTING EQUIPMENT: None.

FIRE AND EXPLOSION HAZARD DATA

STABILITY: (CONDITIONS TO AVOID) Excess heating over long periods of time degrades the resin.
INCOMPATIBILITY: (SPECIFIC MATERIALS TO AVOID) Base.
HAZARDOUS DECOMPOSITION PRODUCTS: None under normal conditions.
HAZARDOUS POLYMERIZATION: Will not occur by itself but masses more than 1 pound of product plus aliphatic amine will cause irreversible polymerization with considerable heat buildup.

ENVIRONMENTAL AND DISPOSAL INFORMATION

ACTION TO TAKE FOR SPILL/LEAKS: Soak up in absorbent material or scrape up. Residual can be removed with non-flammable solvent such as methylene chloride.

DISPOSAL METHOD: Burn in adequate incinerator or bury in an approved landfill.

HEALTH HAZARD DATA

EYE: Minor transient irritation. No corneal injury likely.
SKIN CONTACT: Only minor irritation may be skin sensitizer.
SKIN ABSORBTION: Not likely to be absorbed through skin in toxic amounts

FIRST AID

EYES: Irrigation of the eye immediately with water for five minutes is good safety practice. Consult medical personnel.
SKIN: Contact will probably cause no more than irritation. Wash off in flowing water or shower. Wash clothing before reuse.
INGESTION: Low in toxicity. Induce vomiting if large amounts are ingested.
INHALATION: Remove to fresh air if effect occurs. Consult medical personnel.

NOTE TO PHYSICIAN:
Eyes: Injury is unlikely. Stain for evidence of corneal injury.
Skin: May cause dermatitis. Known or suspect skin sensitizer.
Respiratory: Injury is unlikely.
Oral: Low in toxicity.
Systemic: Human effects not established. No specific antidote. Treatment based on the sound judgment of the physician and the individual reactions of the patients.

HANDLING PRECAUTIONS

VENTILATION: Good room ventilation usually adequate for most operations.
RESPIRATORY PROTECTION: None normally needed.
SKIN PROTECTION: Clean body-covering clothing
EYE PROTECTION: Safety glasses without side shields.

ADDITIONAL INFORMATION

SPECIAL PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: Practice good caution and personnel cleanliness to avoid skin and eye contact Avoid breathing vapors of heated materials.

NFPA HAZARD RATING

4 = EXTREME                HEALTH      1
3 = HIGH                   FIRE        1
2 = MODERATE               REACTIVITY  0
1 = SLIGHT	SPECIFIC
0 = INSIGNIFICANT



COMMERCIAL OR INDUSTRIAL INQUIRIES ONLY PLEASE
  For information email LONE STAR EPOXIES at:  
ls@lsepoxies.com


Lone Star Epoxies
Telephone: (972)475-2501
Fax:(972)412-9036

Lone Star Concrete Epoxy Repair and Sealant P.O. Box 121
Rowlett, Texas
75030-0121
Fischl Enterprises, Inc. dba Lone Star Expoxies

- Decorative Flooring
- Industrial Flooring
- Chemical Resistant Coatings
- Abrasive Surfaces
- U.S.D.A. Approved Materials
- Waterproofing Materials